To download Autodesk Express Viewer please click here.

Categories->SGB-CAPE KWIKSTAGE SYSTEM->FRICTION CLAMP
 
 
FRICTION CLAMP1
 
 1) USE ONLY THE MATERIALS THAT ARE SUPPLIED WITH FRICTION CLAMP. DO NOT USE ANY SUBSTITUTES.

2) REFER TABLE FOR SIZE OF CLAMP APPROPRIATE TO PIPE DIAMETER

3) MAXIMUM OUT OF BALANCE MOMENT FOR ROTATIONAL FORCE IS 4,5kNm.

4) THE LOAD CAPACITY OF FRICTION CLAMP COULD BE ADVERSELY REDUCED BY THE CONDITION OF PIPE SURFACE EG. OILY OR RUSTY.

5)A PROTECTIVE LAYER BETWEEN THE FRICTION CLAMP AND THE PIPE COULD BE USED TO REDUCE DAMAGE OF PAINTWORK ON PIPE.

6) RECOMMEND THE CHAIN TO BE WOUND TWICE AROUND SMALL DIAMETER PIPES.

7)ENSURE THAT THE CHAIN IS NOT TWISTED OR OVER-LAPPED WHEN WOUND AROUND THE PIPE.

8) CHOOSE A SUITABLE LINK TO FIT INTO THE GRAB HOOK AND TIGHTEN THE TENSIONING NUTS- WITH THE TORQUE WRENCH-TO HOLD THE CLAMP IN THE CORRECT POSITION.

9) TORQUE THE TENSIONING NUTS TO 120 Nm.

10) THE SCAFFOLDING MAY NOW BE CONNECTED TO THE FRICTION CLAMP BUT NOT TO EXCEED OUT OF BALANCE MOMENT OF 4,5 kNm.

N.B: CHAIN MAY BE LENGTHENED USING McKINNON HAMMERLOCK & CHAIN. (GRADE 800)
CodeMassSizeMinMax
TFC326 KG300MM500MM900MM
TFC631 KG600MM950MM2000MM
 
 
 

 

 

 